@air
2025-04-15

19. What is the amount of air that may be consumed by the sampling flow of the online monitoring system?

A. 0.1-0.3m³/min
B. 1-3m³/min
C. 5-10m³/min
D. 10-15m³/min

Answer: A
parsing: The sampling flow of monitoring equipment is usually 0.1-0.3m³/min.

Welcome!

Related Articles:
@air
2025-04-15

14. The nominal displacement of an air compressor is 20m³/min, and the measured gas production is 16.8 m ³/min. The possible reasons are not included?

A. An altitude of 1500 meters causes intake pressure loss B. After-treatment equipment pressure loss 6% C. The capacity of the air storage tank is too large D. The ambient temperature is too high Answer: C Analysis: Insufficient capacity of the gas storage tank is a problem. Too large will not affect the gas production…

@ggao
2025-03-12

Does the GWL Series compressor generate radial and axial forces during operation?

Answer: No, the GWL Series compressor has a reasonable structure and only generates rotational force during operation, without radial and axial forces.

@air
2025-04-15

What are the compression elements of piston air compressors?

A. Screw B. Piston C. Centrifugal wheel D. Scroll disk answer: B. piston

@ggao
2025-03-12

What is special about the screw and star wheel structure of the GWL Series compressor?

Answer: The screw and star wheel are designed for high efficiency and long life, with precise tolerances to ensure smooth operation.

@ggao
2025-03-12

Question: What are the demand points for the GWL Series compressor in the pharmaceutical industry?

Answer: It must meet strict standards for purity and reliability to ensure the quality of pharmaceutical products.