@ggao
2025-03-12

Question: How to properly connect the inlet and outlet water pipes of the compressor?

Answer: Follow the manufacturer’s instructions for pipe sizing, connections, and routing.

Welcome!

Related Articles:
@ggao
2025-03-12

Question: What parameters can the smart monitoring system monitor in real-time?

Answer: It can monitor parameters such as discharge pressure, temperature, motor current, and lubrication water level.

@air
2025-04-15

11. What is the accuracy of the flowmeter recommended for energy efficiency monitoring?

A.±0.5% B.±1.5% C.±2.5% D.± 5% Answer: B Analysis: The accuracy of flow meters complying with GB/T 13466 standard is ± 1.5%.

@ggao
2025-03-12

How is the noise level of the GWL Series compressor?

Answer: The noise level is relatively low, typically below [Z] dB(A).

@air
2025-04-15

What are the main standards for air compressors in the medical industry?

A. General Standard B. Medical Standard C. Industry Standard D. No standard answer required: B. medical standard

@air
2025-04-15

19. What is the amount of air that may be consumed by the sampling flow of the online monitoring system?

A. 0.1-0.3m³/min B. 1-3m³/min C. 5-10m³/min D. 10-15m³/min Answer: A Analysis: The sampling flow of monitoring equipment is usually 0…