14. The nominal displacement of an air compressor is 20m³/min, and the measured gas production is 16.8 m ³/min. The possible reasons are not included?
A. Loss of intake pressure due to altitude of 1500 meters
B. Post-treatment equipment pressure loss 6%
C. Air storage tank capacity is too large
D. ambient temperature is too high
Answer: C
parsing: Insufficient capacity of the gas storage tank is a problem. Too large will not affect the gas production.